    摘要:

    针对倾斜螺旋杆式排肥装置作业时存在施肥均匀性差的问题,在龙舟2FH系列排肥装置上进行螺旋部件结构运动参数的优化与验证。通过对装置充、排肥过程分析,探究其装置结构参数与运行参数对排肥均匀性的影响,根据排肥量要求确定其排肥部件因素参数范围。采用单因素试验,以排肥量均值和排肥均匀性变异系数为作业质量评价指标,确定Y形排肥管倾角、输送螺杆螺距、输送螺杆转速的参数范围。采用L9(33)正交表设计试验,根据极差分析和方差分析,获得最优参数组合为:Y形排肥管倾角40°、输送螺杆螺距36 mm、输送螺杆转速170 r/min。台架试验时,设置装置行进速度为0.25 m/s,其排肥量均值和排肥均匀性变异系数分别为3.48 g和14.9%,较优化前装置的排肥量均值提高了0.78 g,排肥均匀性变异系数降低了9.1个百分点。

    Abstract:

    To address the problem of poor fertilization uniformity in the spiral inclined fertilization device during operation, optimization and verification of the structural and motion parameters of the spiral components were carried out on the Longzhou 2FH series fertilizer-discharging device. By analyzing the fertilizer-filling and discharging processes of the device, the influence of its structural and operating parameters on fertilization uniformity was explored. Based on the requirements of fertilizer-discharging amount, the parameter ranges of the fertilizer-discharging components were determined. Single-factor tests were carried out with the average fertilizer-discharging amount and the coefficient of variation of fertilization uniformity as the operation quality evaluation indicators, and the parameter ranges of the inclination angle of the Y-shaped fertilizer-discharging pipe, the pitch of the conveying screw, and the rotational speed of the conveying screw were determined. An L9(33) orthogonal array was used to design the test. According to range analysis and variance analysis, the optimal combined parameters, the inclination angle of the Y-shaped fertilizer-discharging pipe 40°, the pitch of the conveying screw 36 mm, and the rotational speed of the conveying screw 170 r/min were obtained. In the bench-test, with the traveling speed of the device at 0.25 m/s, the average fertilizer-discharging amount and the coefficient of variation of fertilization uniformity were 3.48 g and 14.9%, respectively. Compared with the device before optimization, the average fertilizer-discharging amount increased by 0.78 g, and the coefficient of variation of fertilization uniformity decreased by 9.1 percentage points.

    参考文献
    相似文献
    引证文献
引用本文

张雅蓉,刘大为*,谢方平,郑鹏,宋思明.水稻侧深施肥倾斜螺旋杆式排肥装置参数优化与试验[J].湖南农业大学学报:自然科学版,2024,50(6):.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2025-01-17
  • 出版日期:
文章二维码